Green energy

Green energy: solar, storage and charging with design before purchase

Modules, batteries and chargers are engineering decisions before they are catalogue decisions. A feasibility study built on 12 months of bills, a structural check, a design that integrates with your board, utility homologation and metered commissioning — in that order the investment repays and the installation stays safe.

Photovoltaic generation Electric vehicle charging Battery storage Utility homologation
Work fronts

Six ways to add clean energy to the system you already have

Not every case needs rooftop modules, and not every roof takes modules. The work starts by identifying which front makes sense for your load, your property and your contract with the distributor.

Rooftop photovoltaic generation

Grid-tied system integrated into the board, with balanced strings, surge protection, dedicated earthing and room to grow. The roof is verified first: structure, orientation, shading and safe access for maintenance.

  • Study built on 12 months of load
  • Structural check included
  • Self-consumption ahead of surplus

Ground-mounted, remote or shared generation

When the roof does not work or is not yours: a plant on land, remote self-production or a shared generation arrangement. Here the study is as regulatory as it is electrical, because the framework decides who receives the credit.

  • Compensation rules analysed
  • Array and cable with real voltage drop
  • Injection point agreed with the utility

Electric vehicle charger

From a single home point to a condominium with twelve bays: dedicated circuit, residual current protection suited to dc fault current, load balancing across chargers and a cost-splitting rule that does not turn into an assembly fight.

  • NBR 17019 and NBR 16690 applied
  • Dynamic management of available load
  • Infrastructure ready for more bays

Battery storage

A battery has a clear use case: shifting the peak, holding essential load during an outage, or raising self-consumption for sites that work by day and consume by night. Outside those cases the payback rarely closes — and I say so before the quote.

  • Use case defined by metering
  • Essential load listed and measured
  • Protection and discrimination revisited

Efficiency combined with generation

Cutting load first reduces module count, cable length and contract value. The same roof then serves more useful load, and cheap surplus credit stops being the main destination of your energy.

  • Audit before sizing
  • Baseline recalculated
  • One design, no rework between fronts

Report, homologation and maintenance

An installed system gets an inspected survey: insulation, continuity, string by string, connector thermography and a review of fixings. It is the document insurers, head offices and the utility ask for — and the one that prevents a badly crimped connector from heating up.

  • Report with its own ART
  • String test and output verification
  • Maintenance and cleaning plan
Delivery process

From feasibility to commissioning, in six stages

Each stage has a deliverable and an acceptance criterion. Skipping the first one is what produces a handsome array and a nearly identical bill.

Feasibility

Reading of 12 months of bills, hourly profile, available area, orientation and shading, plus a conversation about load growth and contract changes. The output is a verdict: worth it, not worth it, or worth it in another arrangement.

3 to 7 days

Sizing

Power and string arrangement chosen, month-by-month generation simulation, self-consumption versus surplus defined, and payback expressed as a band. Two or three investment options, each with its stated criterion.

3 to 5 days

Integration design

Single-line diagram drawn over what already exists, AC and DC boards, protection, earthing, lightning protection where applicable, cable routing, signage and structural verification of the roof. Design ART filed.

5 to 10 days

Utility homologation

Access request filed, access opinion followed up, requirements answered and the system placed under the right compensation framework. That clock belongs to the regulator, not to me — which is why I plan the site date with contingency.

10 to 60 days

Installation

Execution with a checklist for crimping, torque, continuity, insulation and earthing, with photographic records per string. Coordination with the local electrical crew and full NR-10 and NR-35 discipline on the roof.

2 to 10 days

Commissioning

Every string tested under real conditions, production compared against the simulation, inverter firmware adjusted, monitoring configured, staff trained on reading the indicators, and the dossier delivered with the report.

1 to 2 days
Deliverables

What you receive in a green energy design

One package that serves three readers: whoever installs it, whoever approves it at the utility, and whoever signs the financing or the internal investment approval.

Standard generation and charging package

  • Feasibility verdict with positive, neutral and negative scenarios
  • Sheets with module layout, cable routing and inverter position
  • AC and DC single-line diagram with protection, isolation and connection point
  • String calculation with open-circuit voltage, short-circuit current and conductor size
  • Monthly generation estimate with declared loss factors
  • Load curve crossed with generation: self-consumption, surplus and most valuable hour
  • Payback as a band, with and without the efficiency measures
  • Material specification and quantified bill of materials for tendering
  • Paperwork for the utility filing plus the filed ART record
  • Commissioning checklist and annual maintenance plan

Homologation is not bureaucracy

The access opinion is the document that states accepted power, connection point, metering system and compensation rules. Designing without it risks rework on a board already installed. I follow the filing and answer utility requirements within the same scope, until approval.

Approval timeline questions

Standards and rules

What holds every decision of the system up technically

Generation, charging and storage touch the electrical design, the utility regulation and the manufacturer warranty at the same time. The list below is what appears in the specification.

Technical and regulatory references used in green energy designs.
Reference What it demands What it affects
NBR 16690 Design requirements for the electrical installation of PV arrays: dc conductors, protection, isolation and identification String layout, solar cable, DC box and live isolation
NBR 5410 Low voltage integration: sizing, residual current protection, discrimination, earthing and voltage drop Integration board, dedicated circuit and declared RCD bypass
NBR 17019 EV charging infrastructure in buildings, with performance requirements and verification procedure Garage, per-unit cost splitting, load reserve and expansion plan
NBR 5419 Interaction with lightning protection, bonding and safe separation distances Roof fixings, earth grid and generator earthing
ANEEL Resolution 1.000/2021 Access rules: request, review, access opinion, deadlines and metering system Homologation schedule and the power the network accepts
Law 14.300/2022 (GD framework) Credit compensation rules, gradual payment of the decentralised contracting wire and rights acquired by date The assumptions behind the payback shown in the study

Your distributor regulations and the local fire brigade instructions may add specific requirements. The specification cites the standard, the resolution and the document of the approving body, in the order in which each decision is taken.

Photovoltaic panels on a roof with inverter and integration board alongside Report and ART for the system dossier
Design before purchase

The system is approved three times: on the roof, in the board, on the network

Modules are the visible part of the investment. What decides the outcome is what nobody photographs: the structure carrying the array, the space left in the board, the cable length that limits voltage and the connection point the utility will accept.

  • Roof: structure, penetrations, access and shading checked across four seasons
  • Board: ampere reserve, busbar, protection and real physical space
  • Network: access opinion, bidirectional metering and injection rules
  • Operation: generation read per string and an annual cleaning plan
  • Risk: documentation for insurer, head office and third-party maintenance
Estimator

Before the array: how much can be cut from today's load?

Every kilowatt-hour that stops existing is a kilowatt-hour the system does not have to generate. Drag the sliders to size the efficiency that should precede generation investment — the output is a band, not a promise.

12 kW
28 %

Educational estimate. The final figure depends on metering, tariff and consumption window.

Estimate

766 per month

per year: R$ 9.193

806 kWh kWh avoided/month
716,08 t CO₂ avoided
42.965 trees eq.
18 months Payback
Next step

Send the bill, the plan and a photo of the roof

With those three I can return a preliminary feasibility verdict, indicate the likely power and warn you of any structural or regulatory blocker. The design proposal follows, with scope and timeline per stage.

Frequently asked questions

How long does a solar system take to pay for itself?
As a rule, 3 to 7 years for self-consumption at low voltage, depending on local tariff, hourly profile and investment price. The window shortens when most load runs in sunshine hours and lengthens when almost everything is consumed at night. That is why the study shows a payback band, an internal rate of return band and the scenario without efficiency measures — never one tidy number.
Does shading from a tree, a neighbour or a water tank kill the design?
It can, which is why it is measured before anything is quoted. I assess shadow across the four seasons and the generation hours, split strings, choose module orientation and, where needed, use power optimisers or microinverters. One shaded row in winter can cost 10% to 25% of the energy of one string — information that never shows in a roof photograph.
Will my roof carry the array?
This is the question that stops most sites after work has started. I check covering type, structure, fixing points, tile condition and fragile surfaces, plus cable routing and maintenance access. On steel structures I work with the structural lead; on old roofing the correct answer is often reinforcement, partial reinforcement or ground-mounted generation.
Do I need a permit or a licence to install?
In most cases a regular building needs no new building permit for rooftop microgeneration, though the municipality may require prior notice and the fire brigade may have requirements for larger structures. The genuinely mandatory path is the access request to the distributor, which issues the opinion stating connection point, metering and accepted power. I gather that paperwork inside the design so the work is not embargoed.
How do the module and inverter warranties work?
They are different warranties: modules usually carry a commercial guarantee plus a long-term performance guarantee with a stated annual degradation, while the inverter has a much shorter term and is the part that drives most system maintenance. The design influences inverter life — string voltage inside range, ventilation, surge protection and accessible isolation. I record all of it in a report when the goal is to keep the warranty valid.

What changes in the electrical design when generation enters

A generator is not simply a source that injects. From the moment it exists, circuits that were passive can have two sources, current direction changes, isolation needs visible identification, and residual current protection may need a declared bypass. At the same time the board gains a busbar where load and generation add vectorially, which changes the effective current in every conductor. This is exactly where the low voltage standard and the photovoltaic array standard cross — and this is where a design drawn only by a kit seller usually fails.

  • Isolation on AC and on DC, identified and reachable in an emergency
  • Lower effective current in the upstream section of the integration board
  • Surge protection sized with the generator in service
  • Array earthing and bonding reviewed together with the new structure

Storage and charging: when they belong in the same design

A battery is justified by three clear hypotheses: shifting consumption out of the peak, keeping essential load alive during an outage, or raising self-consumption where the site runs by day. Vehicle charging is justified when there is idle capacity in the board — and it is almost always the charger that sets the size of future expansion, not the array. When all three appear together the order of the study matters: measure the load, cut the waste, size the generation, then the battery, and only at the end the charging power.

  • Charging power set by the board, not by the wish to charge within one hour
  • Battery sized on measured essential load, with the critical circuit list attached
  • Busbar and physical space reserve planned from the first design
  • Software load management before renegotiating the demand contract
Talk to the technical lead

Let us size your savings before the design is signed off

Typical reply within 4 business hours · Worldwide from Brazil

WhatsApp Telegram Send e-mail Quote